Northeast Ohio Valley Directions to 4350 |
||||||||
|
Conditioned Computer Space The building contains over 20,000 square feet of climate controlled computer space with raised floors, 24-hour air conditioning, UPS back-up, and 9 foot ceilings. Life Safety/Building Features Security System The building security system includes card readers at entrance points and door monitoring on the emergency exit doors. There is a multi-camera CCTV system that monitors interior and exterior locations. Fire Protection The fire alarm system is a device addressable system. The East tower has smoke detector coverage through out the office area. The HVAC systems are monitored by duct detectors. The sprinkler system water flow and valve tamper switches are monitor by the fire alarm system. The occupant notification devices are combination horn/ strobe units. The West tower is fully sprinklered and the East Tower is partly sprinklered with full sprinkler coverage of the East 5 office area. There is a fire pump in the West tower that maintains pressure on the sprinkler systems in both the East and West towers. Public Address System There is a building wide public address system. Elevators and Deliveries Elevators There are 3 passenger elevators and one 6,500 pound capacity service elevator in the East tower that serve all floors. The West Tower has 3 passenger elevators, one 6,500 pound capacity service elevator, that serves all floors and 1 hydraulic service elevator for the cafeteria kitchen that serves 2 floors. Loading Dock 2 truck doors 8 feet x 8 feet with leveling plates 1 truck door 10 feet x 10 feet with leveling plate Restrooms East 1-2 1 Men’s - 4 Stalls and 3 Urinals 1 Women’s - 2 Stalls East 3-5 2 Men’s - 4 Stalls and 3 Urinals 2 Women’s - 2 Stalls West 1 1 Men’s - 3 Stalls and 3 Urinals 1 Women’s - 3 Stalls West 2 1 Men’s - 7 Stalls and 3 Urinals 1 Women’s - 3 Stalls West 3-5 1 Men’s - 7 Stalls and 4 Urinals 1 Women’s - 4 Stalls Additional restrooms adjacent to the Auditorium, Cafeteria, Locker Rooms Lighting The building lighting in the office areas is primarily 1x4 foot fixtures with 2 – T8 lamps. The building has a lighting control system that operates the lights on a schedule programmed for weekday occupancy and weekend and holiday unoccupied cycles. There is an operator override at the security station. Ceiling height in the office areas is 9 feet. Note: Certain building features currently exist at the building, and are subject to change or discontinuance. |
Contact Information
Executive Vice President 412.261.0200 ext. 480
Vice President 412.261.0200 ext. 493 |
||||||||
|
© 2010 Oxford Realty Services • One Oxford Centre • Suite 400 • Pittsburgh, Pennsylvania 15219 |
|||||||||